This MBBR effluent treatment plant for automobile service station / car wash is sized at a sample flow of 10 KLD. Plot about 10.1 × 13.9 m (140 m²). Power: 3.7 kW connected, about 27 kWh a day. Computed outlet meets EP Rules Sch I Sl. 114 (automobile service station) for the parameters computed (COD, TSS, Oil & grease). Not computed here: pH and with metal pre-treatment; checked in detailed design. Budget: on request.

Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·

Design summary

ItemValue
Design flow10 KLD
Flow over running hours0.62 m³/h (16 h/day)
Flow averaged over 24 h0.42 m³/h
TechnologyMBBR
Plot (footprint)10.1 × 13.9 m (140 m²)
Connected load3.7 kW
Operating load2 kW
Energy per day27 kWh
Energy per m³2.68 kWh/m³
Blower air (all duty blowers)21 Nm³/h
Design methodNBW practice

Treatment units and sizes

UnitPurposeVolumeSizeSizing basis
Oil and grease trapremoves floating oil and grease1.3 m³1.2 × 1.2 × 0.9 moil and grease trap at the peak inflow
Equalisation tankstores and evens out the inflow5 m³1.55 × 1.55 × 2.1 mstores the inflow of the 8 h a day the plant does not run, x 1.5 for peaks; air for mixing only, no treatment credit
MBBR tank, 2 stages (sieve baffle)biological treatment: BOD and ammonia removal3.9 m³1.2 × 1.2 × 2.7 mlarger of 6 h on the running flow and the tank for the media needed for BOD + ammonia removal; media 1.2 m3 (30 % fill), 2 stages, fine-bubble air
Tube settler (hopper bottom)settles the biological sludge3.9 m³1.2 × 1.2 × 2.7 mtube settler, surface loading 0.43 m3/m2/h on the running flow, 6.2 h
Chlorine contact tankdisinfection (chlorine contact)1.4 m³1.2 × 1.2 × 1 mchlorine contact on the running flow
Pressure sand filter, FRP 12x52 inchremoves suspended solidsØ 0.3 m × 1.32 m high0.6 m3/h at 8.6 m/h filtration velocity
Activated carbon filter, FRP 16x65 inchremoves colour, odour and chlorineØ 0.41 m × 1.65 m high0.6 m3/h at 4.8 m/h filtration velocity
Treated water tankstores the treated water3.9 m³1.2 × 1.2 × 2.7 mtreated water storage, about 8 h of average flow
Sludge holding tankholds the excess sludge3.9 m³1.2 × 1.2 × 2.7 mabout 7 days of sludge, air mixed
Twin lobe air blowerair for aeration and mixing21 Nm3/h at 3.7 m water column, 1 working + 1 standby (serves eq, mbbr, sludge)

Tank sizes are length × width × depth; vessel sizes are diameter × height.

Water quality, stage by stage

mg/L, computed.
StageBODCODTSSNH₃-NTotal NOil & grease
Inlet1504003002020100
Basket screen (inlet chamber)1504003002020100
Oil and grease trap142.5381.2300202040
Equalisation tank142.5381.2300202040
MBBR bioreactor7.141.9300114.98
Tube settler6.139.230114.98
Disinfection6.139.230114.98
Pressure sand filter4.535.415114.98
Activated carbon filter32315114.98
Outlet32315114.98

Outlet vs EP Rules Sch I Sl. 114 (automobile service station)

EP Rules 1986 Sch. I Sl. 114, automobile service station, bus depot or workshop (G.S.R. 952(E), 2019). Source: Sch. I Sl. 114, ins. by G.S.R. 952(E) dated 26-12-2019. Applies to: inland surface water, land for irrigation or public sewer. mg/L.
ParameterLimitComputed outletResult
COD≤ 15023Within limit
TSS≤ 5015Within limit
Oil & grease≤ 108Within limit

Not computed in this estimate — checked in detailed design:

  • pH 6.5-8.5
  • with metal pre-treatment: dissolved phosphate (as P) 5 mg/L, zinc 5 mg/L

Design assumptions

  • Raw inlet BOD 150 mg/L
  • Raw inlet COD 400 mg/L
  • Raw inlet TSS 300 mg/L
  • Raw inlet TKN 20 mg/L
  • Raw inlet oil and grease 100 mg/L
  • Raw inlet pH 7.5
  • Raw TDS 1,500 mg/L
  • Design temperature 15–32 °C
  • Checked against: EP Rules Sch I Sl. 114 (automobile service station)
  • Plant running 16 hours a day
  • Flow basis: about 150-250 L per car washed
  • Discharge assumed: inland surface water (assumed; the consent decides)
  • Inlet quality: ASSUMED typical values from published ranges for the industry; the plant is designed on the unit's own lab report
  • Note: oil and grease trap ahead; recycle for washing is common

Design checks

  • screen type: a channel bar screen reaches only 0.03 m/s at a buildable width: basket screen (10 mm) in a 1 x 1 m inlet chamber instead
  • Sludge transfer pump: delivery velocity (DN15): flow too small for the smallest pipe to reach 0.6 m/s; accept or run the pump on a timer at a higher velocity
  • Activated carbon filter: filtration velocity: smallest standard vessel runs below the velocity range; fine (more contact), or a smaller vessel

Budget

On request. Ask for a budget estimate for your site.

What quotes often exclude

  • GST
  • Land and civil building / shed
  • Site work: excavation, piling, dewatering
  • Power connection up to the plant panel
  • Consent (CTE / CTO) fees and liaison
  • Operation and maintenance after commissioning

Check your SPCB consent

The State Pollution Control Board consent (CTE / CTO) for your project sets the outlet limits the plant must meet, which can be stricter than the national norm. Check it before you finalise the design: STP discharge norms explained.

Frequently asked questions

What size of tanks does a 10 KLD automobile service station / car wash ETP need?

About 23 m3 of tanks in all: oil and grease trap 1.3 m3; equalisation tank 5 m3; mbbr tank 3.9 m3; tube settler (hopper bottom) 3.9 m3; chlorine contact tank 1.4 m3; treated water tank 3.9 m3; sludge holding tank 3.9 m3.

How much space and power does a 10 KLD automobile service station / car wash ETP need?

A plot about 10.1 x 13.9 m including the equipment room; 3.7 kW connected, 2 kW running, about 27 kWh a day (2.68 kWh per m3) at 16 h a day.

Does a 10 KLD automobile service station / car wash ETP meet the service station standard (EP Rules Sch. I Sl. 114)?

Computed outlet BOD 3, COD 23, TSS 15 mg/L against the service station standard (EP Rules Sch. I Sl. 114) COD 150, TSS 50 mg/L: within the limits. Its other parameters (pH and those listed on this page) are not computed in this estimate; checked in detailed design.

Related

Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.

How we calculate: our design method and sources. For a detailed quotation, request a quote.