Effluent treatment plants by industry
Effluent treatment plant for automobile service station / car wash
This MBBR effluent treatment plant for automobile service station / car wash is sized at a sample flow of 10 KLD. Plot about 10.1 × 13.9 m (140 m²). Power: 3.7 kW connected, about 27 kWh a day. Computed outlet meets EP Rules Sch I Sl. 114 (automobile service station) for the parameters computed (COD, TSS, Oil & grease). Not computed here: pH and with metal pre-treatment; checked in detailed design. Budget: on request.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 10 KLD |
| Flow over running hours | 0.62 m³/h (16 h/day) |
| Flow averaged over 24 h | 0.42 m³/h |
| Technology | MBBR |
| Plot (footprint) | 10.1 × 13.9 m (140 m²) |
| Connected load | 3.7 kW |
| Operating load | 2 kW |
| Energy per day | 27 kWh |
| Energy per m³ | 2.68 kWh/m³ |
| Blower air (all duty blowers) | 21 Nm³/h |
| Design method | NBW practice |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Oil and grease trap | removes floating oil and grease | 1.3 m³ | 1.2 × 1.2 × 0.9 m | oil and grease trap at the peak inflow |
| Equalisation tank | stores and evens out the inflow | 5 m³ | 1.55 × 1.55 × 2.1 m | stores the inflow of the 8 h a day the plant does not run, x 1.5 for peaks; air for mixing only, no treatment credit |
| MBBR tank, 2 stages (sieve baffle) | biological treatment: BOD and ammonia removal | 3.9 m³ | 1.2 × 1.2 × 2.7 m | larger of 6 h on the running flow and the tank for the media needed for BOD + ammonia removal; media 1.2 m3 (30 % fill), 2 stages, fine-bubble air |
| Tube settler (hopper bottom) | settles the biological sludge | 3.9 m³ | 1.2 × 1.2 × 2.7 m | tube settler, surface loading 0.43 m3/m2/h on the running flow, 6.2 h |
| Chlorine contact tank | disinfection (chlorine contact) | 1.4 m³ | 1.2 × 1.2 × 1 m | chlorine contact on the running flow |
| Pressure sand filter, FRP 12x52 inch | removes suspended solids | Ø 0.3 m × 1.32 m high | 0.6 m3/h at 8.6 m/h filtration velocity | |
| Activated carbon filter, FRP 16x65 inch | removes colour, odour and chlorine | Ø 0.41 m × 1.65 m high | 0.6 m3/h at 4.8 m/h filtration velocity | |
| Treated water tank | stores the treated water | 3.9 m³ | 1.2 × 1.2 × 2.7 m | treated water storage, about 8 h of average flow |
| Sludge holding tank | holds the excess sludge | 3.9 m³ | 1.2 × 1.2 × 2.7 m | about 7 days of sludge, air mixed |
| Twin lobe air blower | air for aeration and mixing | 21 Nm3/h at 3.7 m water column, 1 working + 1 standby (serves eq, mbbr, sludge) |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | BOD | COD | TSS | NH₃-N | Total N | Oil & grease |
|---|---|---|---|---|---|---|
| Inlet | 150 | 400 | 300 | 20 | 20 | 100 |
| Basket screen (inlet chamber) | 150 | 400 | 300 | 20 | 20 | 100 |
| Oil and grease trap | 142.5 | 381.2 | 300 | 20 | 20 | 40 |
| Equalisation tank | 142.5 | 381.2 | 300 | 20 | 20 | 40 |
| MBBR bioreactor | 7.1 | 41.9 | 300 | 1 | 14.9 | 8 |
| Tube settler | 6.1 | 39.2 | 30 | 1 | 14.9 | 8 |
| Disinfection | 6.1 | 39.2 | 30 | 1 | 14.9 | 8 |
| Pressure sand filter | 4.5 | 35.4 | 15 | 1 | 14.9 | 8 |
| Activated carbon filter | 3 | 23 | 15 | 1 | 14.9 | 8 |
| Outlet | 3 | 23 | 15 | 1 | 14.9 | 8 |
Outlet vs EP Rules Sch I Sl. 114 (automobile service station)
| Parameter | Limit | Computed outlet | Result |
|---|---|---|---|
| COD | ≤ 150 | 23 | Within limit |
| TSS | ≤ 50 | 15 | Within limit |
| Oil & grease | ≤ 10 | 8 | Within limit |
Not computed in this estimate — checked in detailed design:
- pH 6.5-8.5
- with metal pre-treatment: dissolved phosphate (as P) 5 mg/L, zinc 5 mg/L
Design assumptions
- Raw inlet BOD 150 mg/L
- Raw inlet COD 400 mg/L
- Raw inlet TSS 300 mg/L
- Raw inlet TKN 20 mg/L
- Raw inlet oil and grease 100 mg/L
- Raw inlet pH 7.5
- Raw TDS 1,500 mg/L
- Design temperature 15–32 °C
- Checked against: EP Rules Sch I Sl. 114 (automobile service station)
- Plant running 16 hours a day
- Flow basis: about 150-250 L per car washed
- Discharge assumed: inland surface water (assumed; the consent decides)
- Inlet quality: ASSUMED typical values from published ranges for the industry; the plant is designed on the unit's own lab report
- Note: oil and grease trap ahead; recycle for washing is common
Design checks
- screen type: a channel bar screen reaches only 0.03 m/s at a buildable width: basket screen (10 mm) in a 1 x 1 m inlet chamber instead
- Sludge transfer pump: delivery velocity (DN15): flow too small for the smallest pipe to reach 0.6 m/s; accept or run the pump on a timer at a higher velocity
- Activated carbon filter: filtration velocity: smallest standard vessel runs below the velocity range; fine (more contact), or a smaller vessel
Budget
On request. Ask for a budget estimate for your site.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Check your SPCB consent
The State Pollution Control Board consent (CTE / CTO) for your project sets the outlet limits the plant must meet, which can be stricter than the national norm. Check it before you finalise the design: STP discharge norms explained.
Frequently asked questions
What size of tanks does a 10 KLD automobile service station / car wash ETP need?
About 23 m3 of tanks in all: oil and grease trap 1.3 m3; equalisation tank 5 m3; mbbr tank 3.9 m3; tube settler (hopper bottom) 3.9 m3; chlorine contact tank 1.4 m3; treated water tank 3.9 m3; sludge holding tank 3.9 m3.
How much space and power does a 10 KLD automobile service station / car wash ETP need?
A plot about 10.1 x 13.9 m including the equipment room; 3.7 kW connected, 2 kW running, about 27 kWh a day (2.68 kWh per m3) at 16 h a day.
Does a 10 KLD automobile service station / car wash ETP meet the service station standard (EP Rules Sch. I Sl. 114)?
Computed outlet BOD 3, COD 23, TSS 15 mg/L against the service station standard (EP Rules Sch. I Sl. 114) COD 150, TSS 50 mg/L: within the limits. Its other parameters (pH and those listed on this page) are not computed in this estimate; checked in detailed design.
Related
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.