Effluent treatment plant for food processing
This physico-chemical + MBBR effluent treatment plant for food processing is sized at a sample flow of 100 KLD. Plot about 21.1 × 25.3 m (534 m²). Power: 38.2 kW connected, about 324 kWh a day. Computed outlet meets EP Rules Sch I Sl. 51 (food / fruit processing) for the parameters computed (BOD, TSS, Oil & grease). Not computed here: pH; checked in detailed design. Budget: on request.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 100 KLD |
| Flow over running hours | 6.25 m³/h (16 h/day) |
| Flow averaged over 24 h | 4.17 m³/h |
| Technology | physico-chemical + MBBR |
| Plot (footprint) | 21.1 × 25.3 m (534 m²) |
| Connected load | 38.2 kW |
| Operating load | 20.2 kW |
| Energy per day | 324 kWh |
| Energy per m³ | 3.24 kWh/m³ |
| Blower air (all duty blowers) | 404 Nm³/h |
| Design method | NBW practice |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Equalisation tank | stores and evens out the inflow | 50.5 m³ | 3.8 × 3.8 × 3.5 m | stores the inflow of the 8 h a day the plant does not run, x 1.5 for peaks; air for mixing only, no treatment credit |
| Neutralisation tank | corrects the pH | 1.1 m³ | 1 × 1.05 × 1.01 m | pH correction to 7.5 |
| Flash mixer | mixes in the coagulant | 0.6 m³ | 0.8 × 0.8 × 1 m | coagulant mixing |
| Flocculator | grows the flocs for settling | 2.2 m³ | 1.3 × 1.3 × 1.28 m | flocculation with polyelectrolyte |
| DAF tank | floats off oil, fat and fine solids | 2.4 m³ | 1.5 × 0.8 × 2 m | dissolved air flotation: oil, fat and fine solids |
| MBBR tank, 2 stages (sieve baffle) | biological treatment: BOD and ammonia removal | 120.8 m³ | 5.85 × 5.9 × 3.5 m | larger of 6 h on the running flow and the tank for the media needed for BOD + ammonia removal; media 48.3 m3 (40 % fill), 2 stages, fine-bubble air |
| Secondary clarifier (hopper bottom) | settles the biological sludge | 25.2 m³ | 2.9 × 2.9 × 3 m | clarifier by surface loading, 6.1 h |
| Chlorine contact tank | disinfection (chlorine contact) | 2.1 m³ | 1.35 × 0.45 × 3.5 m | chlorine contact on the running flow |
| Pressure sand filter, FRP 30x72 inch | removes suspended solids | Ø 0.76 m × 1.83 m high | 4.2 m3/h at 9.1 m/h filtration velocity | |
| Activated carbon filter, FRP 36x72 inch | removes colour, odour and chlorine | Ø 0.91 m × 1.83 m high | 4.2 m3/h at 6.3 m/h filtration velocity | |
| Treated water tank | stores the treated water | 33.6 m³ | 3.1 × 3.1 × 3.5 m | treated water storage, about 8 h of average flow |
| Sludge holding tank | holds the excess sludge | 58.8 m³ | 4.1 × 4.1 × 3.5 m | about 7 days of sludge, air mixed |
| Filter press, 800 x 800 mm, 30 chambers | dewaters the sludge to cake | 800 mm plates, 30 chambers, 445 kg/d wet cake | ||
| Twin lobe air blower | air for aeration and mixing | 404 Nm3/h at 4.5 m water column, 1 working + 1 standby (serves eq, mbbr, sludge) |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | BOD | COD | TSS | NH₃-N | Total N | Oil & grease |
|---|---|---|---|---|---|---|
| Inlet | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Basket screen (inlet chamber) | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Equalisation tank | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Neutralisation tank | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Flash mixer | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Flocculator | 1,200 | 2,000 | 500 | 50 | 50 | 150 |
| Dissolved air flotation (DAF) | 1,200 | 2,000 | 50 | 50 | 50 | 10 |
| MBBR bioreactor | 60 | 214 | 50 | 1 | 7.2 | 2 |
| Secondary clarifier | 51 | 199.9 | 30 | 1 | 7.2 | 2 |
| Disinfection | 51 | 199.9 | 30 | 1 | 7.2 | 2 |
| Pressure sand filter | 38.3 | 179.9 | 15 | 1 | 7.2 | 2 |
| Activated carbon filter | 24.9 | 117 | 15 | 1 | 7.2 | 2 |
| Outlet | 24.9 | 117 | 15 | 1 | 7.2 | 2 |
Outlet vs EP Rules Sch I Sl. 51 (food / fruit processing)
| Parameter | Limit | Computed outlet | Result |
|---|---|---|---|
| BOD | ≤ 30 | 24.9 | Within limit |
| TSS | ≤ 50 | 15 | Within limit |
| Oil & grease | ≤ 10 | 2 | Within limit |
Not computed in this estimate — checked in detailed design:
- pH 6.5-8.5
Design assumptions
- Raw inlet BOD 1,200 mg/L
- Raw inlet COD 2,000 mg/L
- Raw inlet TSS 500 mg/L
- Raw inlet TKN 50 mg/L
- Raw inlet oil and grease 150 mg/L
- Raw inlet pH 6.5
- Raw TDS 1,500 mg/L
- Design temperature 15–32 °C
- Checked against: EP Rules Sch I Sl. 51 (food / fruit processing)
- Plant running 16 hours a day
- Flow basis: about 5-10 m3 per tonne of product
- Discharge assumed: inland surface water (assumed; the consent decides)
- Inlet quality: ASSUMED typical values from published ranges for the industry; the plant is designed on the unit's own lab report
- Note: fat and starch: DAF ahead of the biology
Design checks
- screen type: a channel bar screen reaches only 0.28 m/s at a buildable width: basket screen (10 mm) in a 1 x 1 m inlet chamber instead
Budget
On request. Ask for a budget estimate for your site.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Check your SPCB consent
The State Pollution Control Board consent (CTE / CTO) for your project sets the outlet limits the plant must meet, which can be stricter than the national norm. Check it before you finalise the design: STP discharge norms explained.
Frequently asked questions
What size of tanks does a 100 KLD food processing ETP need?
About 297 m3 of tanks in all: equalisation tank 50.5 m3; neutralisation tank 1.1 m3; flash mixer 0.6 m3; flocculator 2.2 m3; daf tank 2.4 m3; mbbr tank 120.8 m3; secondary clarifier (hopper bottom) 25.2 m3; chlorine contact tank 2.1 m3; treated water tank 33.6 m3; sludge holding tank 58.8 m3.
How much space and power does a 100 KLD food processing ETP need?
A plot about 21.1 x 25.3 m including the equipment room; 38.2 kW connected, 20.2 kW running, about 324 kWh a day (3.24 kWh per m3) at 16 h a day.
Does a 100 KLD food processing ETP meet the food and fruit processing standard (EP Rules Sch. I Sl. 51)?
Computed outlet BOD 24.9, TSS 15 mg/L against the food and fruit processing standard (EP Rules Sch. I Sl. 51) BOD 30, TSS 50 mg/L: within the limits. Its other parameters (pH and those listed on this page) are not computed in this estimate; checked in detailed design.
Related
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.