Effluent treatment plants by industry
Effluent treatment plant for pharmaceutical (formulation)
This physico-chemical + MBBR effluent treatment plant for pharmaceutical (formulation) is sized at a sample flow of 100 KLD. Plot about 20.1 × 24.2 m (486 m²). Power: 28 kW connected, about 233 kWh a day. Computed outlet meets EP Rules Sch I Sl. 73 (bulk drug and formulation) for the parameters computed (BOD, COD, TSS, Oil & grease, NH₃-N). Not computed here: pH, bio-assay and additional parameters set by the state board; checked in detailed design. Budget: on request.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 100 KLD |
| Flow over running hours | 6.25 m³/h (16 h/day) |
| Flow averaged over 24 h | 4.17 m³/h |
| Technology | physico-chemical + MBBR |
| Plot (footprint) | 20.1 × 24.2 m (486 m²) |
| Connected load | 28 kW |
| Operating load | 15 kW |
| Energy per day | 233 kWh |
| Energy per m³ | 2.33 kWh/m³ |
| Blower air (all duty blowers) | 356 Nm³/h |
| Design method | NBW practice |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Oil and grease trap | removes floating oil and grease | 0.9 m³ | 3.45 × 0.3 × 0.9 m | oil and grease trap at the peak inflow |
| Equalisation tank | stores and evens out the inflow | 50.5 m³ | 3.8 × 3.8 × 3.5 m | stores the inflow of the 8 h a day the plant does not run, x 1.5 for peaks; air for mixing only, no treatment credit |
| Neutralisation tank | corrects the pH | 1.1 m³ | 1 × 1.05 × 1.01 m | pH correction to 7.5 |
| Flash mixer | mixes in the coagulant | 0.6 m³ | 0.8 × 0.8 × 1 m | coagulant mixing |
| Flocculator | grows the flocs for settling | 2.2 m³ | 1.3 × 1.3 × 1.28 m | flocculation with polyelectrolyte |
| Tube settler (hopper bottom) | settles the chemical sludge | 5.2 m³ | 1.3 × 1.3 × 3.1 m | chemical sludge settling by surface loading |
| MBBR tank, 2 stages (sieve baffle) | biological treatment: BOD and ammonia removal | 107.8 m³ | 5.55 × 5.55 × 3.5 m | larger of 6 h on the running flow and the tank for the media needed for BOD + ammonia removal; media 42.9 m3 (40 % fill), 2 stages, fine-bubble air |
| Secondary clarifier (hopper bottom) | settles the biological sludge | 25.2 m³ | 2.9 × 2.9 × 3 m | clarifier by surface loading, 6.1 h |
| Chlorine contact tank | disinfection (chlorine contact) | 2.1 m³ | 1.35 × 0.45 × 3.5 m | chlorine contact on the running flow |
| Pressure sand filter, FRP 30x72 inch | removes suspended solids | Ø 0.76 m × 1.83 m high | 4.2 m3/h at 9.1 m/h filtration velocity | |
| Activated carbon filter, FRP 36x72 inch | removes colour, odour and chlorine | Ø 0.91 m × 1.83 m high | 4.2 m3/h at 6.3 m/h filtration velocity | |
| Treated water tank | stores the treated water | 33.6 m³ | 3.1 × 3.1 × 3.5 m | treated water storage, about 8 h of average flow |
| Sludge holding tank | holds the excess sludge | 49.9 m³ | 3.75 × 3.8 × 3.5 m | about 7 days of sludge, air mixed |
| Filter press, 630 x 630 mm, 32 chambers | dewaters the sludge to cake | 630 mm plates, 32 chambers, 277 kg/d wet cake | ||
| Twin lobe air blower | air for aeration and mixing | 356 Nm3/h at 4.5 m water column, 1 working + 1 standby (serves eq, mbbr, sludge) |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | BOD | COD | TSS | NH₃-N | Total N | Oil & grease |
|---|---|---|---|---|---|---|
| Inlet | 1,000 | 3,000 | 300 | 60 | 60 | 20 |
| Basket screen (inlet chamber) | 1,000 | 3,000 | 300 | 60 | 60 | 20 |
| Oil and grease trap | 950 | 2,859 | 300 | 60 | 60 | 8 |
| Equalisation tank | 950 | 2,859 | 300 | 60 | 60 | 8 |
| Neutralisation tank | 950 | 2,859 | 300 | 60 | 60 | 8 |
| Flash mixer | 950 | 2,859 | 300 | 60 | 60 | 8 |
| Flocculator | 950 | 2,859 | 300 | 60 | 60 | 8 |
| Tube settler (chemical sludge) | 950 | 2,859 | 100 | 60 | 60 | 8 |
| MBBR bioreactor | 47.5 | 314 | 100 | 1 | 26.2 | 1.6 |
| Secondary clarifier | 40.4 | 293.9 | 30 | 1 | 26.2 | 1.6 |
| Disinfection | 40.4 | 293.9 | 30 | 1 | 26.2 | 1.6 |
| Pressure sand filter | 30.3 | 265.4 | 15 | 1 | 26.2 | 1.6 |
| Activated carbon filter | 19.7 | 172.5 | 15 | 1 | 26.2 | 1.6 |
| Outlet | 19.7 | 172.5 | 15 | 1 | 26.2 | 1.6 |
Outlet vs EP Rules Sch I Sl. 73 (bulk drug and formulation)
| Parameter | Limit | Computed outlet | Result |
|---|---|---|---|
| BOD | ≤ 30 | 19.7 | Within limit |
| COD | ≤ 250 | 172.5 | Within limit |
| TSS | ≤ 100 | 15 | Within limit |
| Oil & grease | ≤ 10 | 1.6 | Within limit |
| NH₃-N | ≤ 100 | 1 | Within limit |
Not computed in this estimate — checked in detailed design:
- pH 6.0-8.5
- bio-assay: 90 % survival of fish after 96 h in 100 % effluent (IS 6582)
- additional parameters set by the state board: benzene 0.1, xylene 0.12, methylene chloride 0.9, chlorobenzene 0.2, phosphate (as P) 5, sulphide 2, phenolics 1, zinc 5, copper 3, total chromium 2, hexavalent chromium 0.1, cyanide 0.1, arsenic 0.2, mercury 0.01, lead 0.1 mg/L; SAR < 26 on land
Design assumptions
- Raw inlet BOD 1,000 mg/L
- Raw inlet COD 3,000 mg/L
- Raw inlet TSS 300 mg/L
- Raw inlet TKN 60 mg/L
- Raw inlet oil and grease 20 mg/L
- Raw inlet pH 7
- Raw TDS 5,000 mg/L
- Design temperature 15–32 °C
- Checked against: EP Rules Sch I Sl. 73 (bulk drug and formulation)
- Plant running 16 hours a day
- Flow basis: varies by product and wash cycles
- Discharge assumed: inland surface water (assumed; the consent decides)
- Inlet quality: ASSUMED typical values from published ranges for the industry; the plant is designed on the unit's own lab report
- Note: bulk drug (API) units with high TDS / solvents usually need ZLD; not sized here
Design checks
- screen type: a channel bar screen reaches only 0.28 m/s at a buildable width: basket screen (10 mm) in a 1 x 1 m inlet chamber instead
- alkalinity after nitrification (before dosing): short of alkalinity: NaHCO3 dosed to keep pH >= 6.8
Budget
On request. Ask for a budget estimate for your site.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Check your SPCB consent
The State Pollution Control Board consent (CTE / CTO) for your project sets the outlet limits the plant must meet, which can be stricter than the national norm. Check it before you finalise the design: STP discharge norms explained.
Frequently asked questions
What size of tanks does a 100 KLD pharmaceutical (formulation) ETP need?
About 279 m3 of tanks in all: oil and grease trap 0.9 m3; equalisation tank 50.5 m3; neutralisation tank 1.1 m3; flash mixer 0.6 m3; flocculator 2.2 m3; tube settler (hopper bottom) 5.2 m3; mbbr tank 107.8 m3; secondary clarifier (hopper bottom) 25.2 m3; chlorine contact tank 2.1 m3; treated water tank 33.6 m3; sludge holding tank 49.9 m3.
How much space and power does a 100 KLD pharmaceutical (formulation) ETP need?
A plot about 20.1 x 24.2 m including the equipment room; 28 kW connected, 15 kW running, about 233 kWh a day (2.33 kWh per m3) at 16 h a day.
Does a 100 KLD pharmaceutical (formulation) ETP meet the bulk drug and formulation standard (EP Rules Sch. I Sl. 73)?
Computed outlet BOD 19.7, TSS 15 mg/L against the bulk drug and formulation standard (EP Rules Sch. I Sl. 73) BOD 30, COD 250, TSS 100 mg/L: within the limits. Its other parameters (pH and those listed on this page) are not computed in this estimate; checked in detailed design.