RO plants by capacity
10,000 LPH industrial RO plant: sizing, power and running cost
A 10,000 LPH RO plant at 70 % recovery takes about 15,000 L/h of feed water and rejects 4,500 L/h. It uses 18 x 8 inch membranes and a 5.5 kW high-pressure pump. Plot about 14.9 × 13.9 m (207 m²). Power: 25.6 kW connected, about 294 kWh a day. Computed outlet meets IS 10500:2012 for the parameters computed (TDS). Budget: ₹10 L – ₹22 L (typical market range, not an NBW quotation).
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 160 KLD |
| Flow over running hours | 10 m³/h (16 h/day) |
| Flow averaged over 24 h | 6.67 m³/h |
| Plot (footprint) | 14.9 × 13.9 m (207 m²) |
| Connected load | 25.6 kW |
| Operating load | 18.4 kW |
| Energy per day | 294 kWh |
| Energy per m³ | 1.84 kWh/m³ |
| Design method | NBW practice |
RO design
| Item | Value |
|---|---|
| Product water | 10,000 L/h |
| Recovery | 70 % |
| Feed water | 15,000 L/h |
| Reject | 4,500 L/h |
| Membranes | 18 x 8 inch |
| High-pressure pump | 5.5 kW |
| Pretreatment | Multimedia filter; RO feed dosing (SMBS, acid, antiscalant); Cartridge filter, 5 micron |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Raw water tank (client's scope, existing) | raw water storage | 33 m³ | Ø 3.27 m × 3.93 m high | existing tank, client's scope |
| Multimedia filter, MS 1400 mm, 4 mm FRP lined | removes turbidity and suspended solids | Ø 1.4 m × 1.8 m high | 16.2 m3/h at 10.5 m/h filtration velocity | |
| Cartridge filter, 5 micron: 9 x 40 inch elements | protects the membranes (5 micron) | Ø 0.51 m × 1.37 m high | 9 x 40 inch, 5 micron elements | |
| RO skid | removes dissolved salts (reverse osmosis) | 18 x 8 inch elements in 3 pressure vessel(s), array 2:1, flux 14.3 L/m2/h, recovery 70% | ||
| Product (treated) water tank | stores the treated water | 10 m³ | Ø 2.2 m × 2.63 m high | HDPE tank |
| CIP tank | membrane cleaning | 1.5 m³ | Ø 1.17 m × 1.4 m high | HDPE tank |
| CIP cartridge filter, 5 micron: 4 x 40 inch elements | membrane cleaning | Ø 0.39 m × 1.37 m high | 4 x 40 inch, 5 micron elements |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | TDS | Meets norm |
|---|---|---|
| Raw water | 1,500 | No |
| RO permeate | 39.6 | Yes |
| Outlet | 39.6 | Yes |
| Norm limit (IS 10500:2012) | ≤ 500 |
Design assumptions
- Raw water TDS 1,500 mg/L
- Raw water total hardness 450 mg/L as CaCO₃
- Checked against: IS 10500:2012
- Plant running 16 hours a day
- Raw water: ASSUMED typical hard borewell water; the plant is designed on the site's lab report
Design checks
- typical borewell: SIO2 not measured: needed for the membrane projection
- typical borewell: BA not measured: needed for the membrane projection
- typical borewell: SR not measured: needed for the membrane projection
- typical borewell: K not measured: needed for the membrane projection
Budget
Typical market range (published figures, 2026) — not an NBW quotation
| Capacity | RO — raw/process water |
|---|---|
| 200 KLD | ₹10 L – ₹22 L |
| Capacity | RO — raw/process water |
|---|---|
| 200 KLD | ₹13 – 27 per KL |
These are published market figures, not Navbharat Water's prices. For our own estimate for your project, request a quote.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Frequently asked questions
What does a 10000 LPH RO plant need?
18 x 8 inch membranes (array 2:1), feed 15000 L/h, reject 4500 L/h at 70 % recovery; pretreatment: multimedia filter, ro feed dosing (smbs, acid, antiscalant), cartridge filter, 5 micron.
How much space and power does a 10000 LPH RO plant need?
A plot about 14.9 x 13.9 m including the equipment room; 25.6 kW connected, 18.4 kW running, about 294 kWh a day (1.84 kWh per m3) at 16 h a day.
Does a 10000 LPH RO plant meet IS 10500:2012?
Computed outlet TDS 39.6 mg/L against IS 10500:2012 TDS 500 mg/L: within the limits.
Related
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.