RO plants by capacity
250 LPH industrial RO plant: sizing, power and running cost
A 250 LPH RO plant at 70 % recovery takes about 380 L/h of feed water and rejects 110 L/h. It uses 2 x 4 inch membranes and a 0.4 kW high-pressure pump. Plot about 8.2 × 10 m (82 m²). Power: 2.2 kW connected, about 12 kWh a day. Computed outlet meets IS 10500:2012 for the parameters computed (TDS). Budget: on request.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 4 KLD |
| Flow over running hours | 0.25 m³/h (16 h/day) |
| Flow averaged over 24 h | 0.17 m³/h |
| Plot (footprint) | 8.2 × 10 m (82 m²) |
| Connected load | 2.2 kW |
| Operating load | 0.8 kW |
| Energy per day | 12 kWh |
| Energy per m³ | 3.05 kWh/m³ |
| Design method | NBW practice |
RO design
| Item | Value |
|---|---|
| Product water | 250 L/h |
| Recovery | 70 % |
| Feed water | 380 L/h |
| Reject | 110 L/h |
| Membranes | 2 x 4 inch |
| High-pressure pump | 0.4 kW |
| Pretreatment | Multimedia filter; RO feed dosing (SMBS, acid, antiscalant); Cartridge filter, 5 micron |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Raw water tank (client's scope, existing) | raw water storage | 1 m³ | Ø 1.02 m × 1.22 m high | existing tank, client's scope |
| Multimedia filter, FRP 8x44 inch | removes turbidity and suspended solids | Ø 0.2 m × 1.12 m high | 0.4 m3/h at 12.4 m/h filtration velocity | |
| Cartridge filter, 5 micron: 1 x 10 inch elements | protects the membranes (5 micron) | Ø 0.27 m × 0.6 m high | 1 x 10 inch, 5 micron elements | |
| RO skid | removes dissolved salts (reverse osmosis) | 2 x 4 inch elements in 1 pressure vessel(s), array 1, flux 17.3 L/m2/h, recovery 70% | ||
| Product (treated) water tank | stores the treated water | 0.5 m³ | Ø 0.81 m × 0.97 m high | HDPE tank |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | TDS | Meets norm |
|---|---|---|
| Raw water | 1,500 | No |
| RO permeate | 55.7 | Yes |
| Outlet | 55.7 | Yes |
| Norm limit (IS 10500:2012) | ≤ 500 |
Design assumptions
- Raw water TDS 1,500 mg/L
- Raw water total hardness 450 mg/L as CaCO₃
- Checked against: IS 10500:2012
- Plant running 16 hours a day
- Raw water: ASSUMED typical hard borewell water; the plant is designed on the site's lab report
Design checks
- typical borewell: SIO2 not measured: needed for the membrane projection
- typical borewell: BA not measured: needed for the membrane projection
- typical borewell: SR not measured: needed for the membrane projection
- typical borewell: K not measured: needed for the membrane projection
Engineering notes
Points our engineers confirm during detailed design:
- Specific energy is above the usual RO range at this small size (fixed panel, dosing and instrument load on a small output, smallest standard pumps); pump duty is optimised in detailed design
Budget
On request. Ask for a budget estimate for your site.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Frequently asked questions
What does a 250 LPH RO plant need?
2 x 4 inch membranes (array 1), feed 380 L/h, reject 110 L/h at 70 % recovery; pretreatment: multimedia filter, ro feed dosing (smbs, acid, antiscalant), cartridge filter, 5 micron.
How much space and power does a 250 LPH RO plant need?
A plot about 8.2 x 10 m including the equipment room; 2.2 kW connected, 0.8 kW running, about 12 kWh a day (3.05 kWh per m3) at 16 h a day.
Does a 250 LPH RO plant meet IS 10500:2012?
Computed outlet TDS 55.7 mg/L against IS 10500:2012 TDS 500 mg/L: within the limits.
Related
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.