RO plants by capacity
5,000 LPH industrial RO plant: sizing, power and running cost
A 5,000 LPH RO plant at 70 % recovery takes about 7,500 L/h of feed water and rejects 2,250 L/h. It uses 12 x 8 inch membranes and a 3 kW high-pressure pump. Plot about 14.3 × 12.9 m (184 m²). Power: 14.2 kW connected, about 150 kWh a day. Computed outlet meets IS 10500:2012 for the parameters computed (TDS). Budget: ₹6 L – ₹14 L (typical market range, not an NBW quotation).
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 80 KLD |
| Flow over running hours | 5 m³/h (16 h/day) |
| Flow averaged over 24 h | 3.33 m³/h |
| Plot (footprint) | 14.3 × 12.9 m (184 m²) |
| Connected load | 14.2 kW |
| Operating load | 9.4 kW |
| Energy per day | 150 kWh |
| Energy per m³ | 1.87 kWh/m³ |
| Design method | NBW practice |
RO design
| Item | Value |
|---|---|
| Product water | 5,000 L/h |
| Recovery | 70 % |
| Feed water | 7,500 L/h |
| Reject | 2,250 L/h |
| Membranes | 12 x 8 inch |
| High-pressure pump | 3 kW |
| Pretreatment | Multimedia filter; RO feed dosing (SMBS, acid, antiscalant); Cartridge filter, 5 micron |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Raw water tank (client's scope, existing) | raw water storage | 20 m³ | Ø 2.77 m × 3.32 m high | existing tank, client's scope |
| Multimedia filter, MS 1000 mm, 4 mm FRP lined | removes turbidity and suspended solids | Ø 1 m × 1.8 m high | 8.1 m3/h at 10.3 m/h filtration velocity | |
| Cartridge filter, 5 micron: 5 x 40 inch elements | protects the membranes (5 micron) | Ø 0.42 m × 1.37 m high | 5 x 40 inch, 5 micron elements | |
| RO skid | removes dissolved salts (reverse osmosis) | 12 x 8 inch elements in 2 pressure vessel(s), array 1:1, flux 10.7 L/m2/h, recovery 70% | ||
| Product (treated) water tank | stores the treated water | 5 m³ | Ø 1.74 m × 2.1 m high | HDPE tank |
| CIP tank | membrane cleaning | 1 m³ | Ø 1.02 m × 1.22 m high | HDPE tank |
| CIP cartridge filter, 5 micron: 2 x 40 inch elements | membrane cleaning | Ø 0.32 m × 1.37 m high | 2 x 40 inch, 5 micron elements |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | TDS | Meets norm |
|---|---|---|
| Raw water | 1,500 | No |
| RO permeate | 52.8 | Yes |
| Outlet | 52.8 | Yes |
| Norm limit (IS 10500:2012) | ≤ 500 |
Design assumptions
- Raw water TDS 1,500 mg/L
- Raw water total hardness 450 mg/L as CaCO₃
- Checked against: IS 10500:2012
- Plant running 16 hours a day
- Raw water: ASSUMED typical hard borewell water; the plant is designed on the site's lab report
Design checks
- typical borewell: SIO2 not measured: needed for the membrane projection
- typical borewell: BA not measured: needed for the membrane projection
- typical borewell: SR not measured: needed for the membrane projection
- typical borewell: K not measured: needed for the membrane projection
Budget
Typical market range (published figures, 2026) — not an NBW quotation
| Capacity | RO — raw/process water |
|---|---|
| 100 KLD | ₹6 L – ₹14 L |
| Capacity | RO — raw/process water |
|---|---|
| 100 KLD | ₹15 – 30 per KL |
These are published market figures, not Navbharat Water's prices. For our own estimate for your project, request a quote.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Frequently asked questions
What does a 5000 LPH RO plant need?
12 x 8 inch membranes (array 1:1), feed 7500 L/h, reject 2250 L/h at 70 % recovery; pretreatment: multimedia filter, ro feed dosing (smbs, acid, antiscalant), cartridge filter, 5 micron.
How much space and power does a 5000 LPH RO plant need?
A plot about 14.3 x 12.9 m including the equipment room; 14.2 kW connected, 9.4 kW running, about 150 kWh a day (1.87 kWh per m3) at 16 h a day.
Does a 5000 LPH RO plant meet IS 10500:2012?
Computed outlet TDS 52.8 mg/L against IS 10500:2012 TDS 500 mg/L: within the limits.
Related
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.