Guide
What an ETP is, how it works, and what it costs
An effluent treatment plant (ETP) cleans industrial wastewater so it can be reused or discharged within the limits in your State Pollution Control Board consent. It usually has primary (physico-chemical), secondary (biological) and tertiary (filtration, sometimes RO) stages plus sludge handling. Cost depends on capacity and how strong the effluent is: COD, oil, colour and dissolved salts.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
How an ETP works
| Stage | Units | What it removes |
|---|---|---|
| Preliminary | Screens, oil and grease trap, equalisation tank | Rags and grit, free oil; evens out flow and strength |
| Primary (physico-chemical) | pH correction, coagulation and flocculation, clarifier or DAF | Suspended solids, colloids, part of the COD, metals (by precipitation) |
| Secondary (biological) | Activated sludge, MBBR, SBR or MBR; anaerobic stage for very strong effluent | Dissolved organics (BOD, most COD), ammonia |
| Tertiary | Sand and carbon filters, UF, RO where reuse or low TDS is needed | Fine solids, residual COD and colour, dissolved salts (RO) |
| Sludge handling | Thickener, filter press or centrifuge, sludge drying beds | Dewaters sludge for authorised disposal |
Not every ETP needs every stage. A dairy or food plant is mostly biological; an electroplating unit is mostly chemical; textile and pharma usually need both plus tertiary treatment. If you only need to treat toilet and canteen sewage, see STP vs ETP.
Discharge standards by industry
| Industry | Rule | pH | BOD | COD | TSS | Oil & grease | Other |
|---|---|---|---|---|---|---|---|
| Textile | EP Rules Sch I Sl. 6 (G.S.R. 978(E), 2016) | 6.5–8.5 | 30 | 250 | 100 | 10 | Colour 150 PCU, TDS 2,100, total chromium 2, sulphide 2, ammoniacal N 50 |
| Dairy | EP Rules Sch I Sl. 56 | 6.5–8.5 | 100 | — | 150 | 10 | Wastewater 3 m³ per kL of milk |
| Pharmaceutical (bulk drug and formulation) | EP Rules Sch I Sl. 73 (G.S.R. 541(E), 2021) | 6.0–8.5 | 30 | 250 | 100 | 10 | Ammoniacal N 100; bioassay 90% fish survival after 96 h in 100% effluent |
| Sugar | EP Rules Sch I Sl. 4 (G.S.R. 35(E), 2016) | 5.5–8.5 | 30 (100 on land) | — | 30 (100 on land) | 10 | TDS 2,100; final wastewater 200 L per tonne of cane crushed |
| Fermentation (distillery, brewery, maltry) | EP Rules Sch I Sl. 15 | 5.5–9.0 | 30 (100 on land) | — | 100 | — | Colour and odour removed as far as practicable |
| Hospital (bedded) | Bio-Medical Waste Management Rules 2016, Sch II cl. 8 | 6.5–9.0 | 30 | 250 | 100 | 10 | Bioassay 90% survival after 96 h; applies where there is no sewer with a terminal STP |
Where no industry-specific standard applies, the general standards in Schedule VI of the EP Rules are used (for inland surface water: pH 5.5–9.0, TSS 100, BOD 30, COD 250, oil and grease 10 mg/l).
Online monitoring (OCEMS)
CPCB's direction of 5 February 2014 requires the 17 categories of highly polluting industries, and CETPs, to install online effluent monitoring at the ETP outlet for flow, pH, COD, BOD, TSS and other consented parameters, and to upload the data to the SPCB and CPCB servers. The 17 categories are: pharmaceuticals, chlor-alkali, fertilisers, oil refineries, dyes and dye intermediates, pesticides, petrochemicals, large power plants, cement, aluminium, zinc, copper, iron and steel, large pulp and paper, distilleries, sugar and tanneries.
ETP sludge is hazardous waste
- Chemical sludge from wastewater treatment is listed in Schedule I of the Hazardous and Other Wastes Rules 2016 (entry 35.3); evaporation and concentration residues are entry 37.3.
- It must go to an authorised facility such as a TSDF or an authorised user, and can be stored on site for up to 90 days.
- Keep records in Form 3 and file the annual return in Form 4 with the SPCB by 30 June.
Typical market price ranges
Typical market range (published figures, 2026) — not an NBW quotation
| Capacity | ETP — low strength | ETP — medium strength | ETP — high strength |
|---|---|---|---|
| 10 KLD | ₹8 L – ₹15 L | ₹12 L – ₹22 L | ₹18 L – ₹35 L |
| 25 KLD | ₹12 L – ₹25 L | ₹20 L – ₹35 L | ₹30 L – ₹55 L |
| 50 KLD | ₹20 L – ₹40 L | ₹35 L – ₹70 L | ₹50 L – ₹90 L |
| 100 KLD | ₹40 L – ₹80 L | ₹65 L – ₹1.2 Cr | ₹90 L – ₹1.6 Cr |
| 200 KLD | ₹70 L – ₹1.4 Cr | ₹1.1 Cr – ₹2 Cr | ₹1.5 Cr – ₹2.8 Cr |
| 500 KLD | ₹1.5 Cr – ₹3 Cr | ₹2.2 Cr – ₹5 Cr | ₹3.5 Cr – ₹7 Cr |
| 1,000 KLD | ₹2.5 Cr – ₹5 Cr | ₹4 Cr – ₹10 Cr | ₹7 Cr – ₹14 Cr |
| Capacity | ETP — low strength | ETP — medium strength | ETP — high strength |
|---|---|---|---|
| 10 KLD | ₹40 – 70 per KL | ₹55 – 95 per KL | ₹80 – 140 per KL |
| 25 KLD | ₹30 – 55 per KL | ₹42 – 75 per KL | ₹60 – 110 per KL |
| 50 KLD | ₹25 – 45 per KL | ₹35 – 60 per KL | ₹50 – 90 per KL |
| 100 KLD | ₹18 – 35 per KL | ₹25 – 48 per KL | ₹35 – 70 per KL |
| 200 KLD | ₹15 – 30 per KL | ₹21 – 42 per KL | ₹30 – 60 per KL |
| 500 KLD | ₹12 – 25 per KL | ₹17 – 35 per KL | ₹25 – 50 per KL |
| 1,000 KLD | ₹10 – 22 per KL | ₹14 – 30 per KL | ₹20 – 45 per KL |
These are published market figures, not Navbharat Water's prices. For our own estimate for your project, request a quote.
Price categories: low strength (COD below about 3,000 mg/l: food, dairy, beverage); medium (about 3,000–10,000 mg/l: textile, engineering, chemical); high (above 10,000 mg/l: pharma API, specialty chemicals, distillery pre-treatment). Civil tankage may be quoted separately and can add 25–40% on a greenfield site. RO and ZLD stages are not included; see Zero Liquid Discharge.
Before you ask for quotes
- Get a full analysis of your effluent from a NABL-accredited lab: flow over the day, pH, BOD, COD, TSS, oil and grease, TDS, and anything specific to your process (colour, metals, ammonia).
- Check the outlet norm and any reuse or ZLD condition in your consent to establish and operate.
- Decide where treated water goes: reuse in process, gardening, sewer or surface water.
- Compare vendors on the same flow, inlet and outlet basis, and check who handles sludge disposal.
Consent to operate: under the January 2026 amendment to the Water Act consent guidelines (G.S.R. 63(E)), a CTO once granted stays valid until cancelled. Standards on this page are summarised for planning and are not legal advice.
Frequently asked questions
What is the difference between an ETP and an STP?
An STP treats domestic sewage from toilets, kitchens and bathrooms. An ETP treats industrial process wastewater, which can contain chemicals, oil, colour, metals and dissolved salts, so it usually needs physico-chemical treatment as well as biological treatment.
What COD limit must an ETP meet?
For most industries discharging to inland surface water the limit is COD 250 mg/l (EP Rules Schedule VI, and the textile and pharmaceutical standards). Your SPCB consent states the exact limit for your unit.
Which industries need online effluent monitoring (OCEMS)?
The 17 categories of highly polluting industries named by CPCB in its February 2014 direction, including pharmaceuticals, dyes, pesticides, distilleries, sugar, tanneries, pulp and paper, and CETPs.
How is ETP sludge disposed of?
Chemical sludge from wastewater treatment is hazardous waste under the Hazardous and Other Wastes Rules 2016. It must go to an authorised TSDF or user, with records in Form 3 and an annual return in Form 4.
Sources
- Environment (Protection) Rules, 1986, Schedule I (industry-specific standards) and Schedule VI.
- MoEFCC notifications G.S.R. 978(E), 10 October 2016 (textile); G.S.R. 35(E), 14 January 2016 (sugar); G.S.R. 541(E), 6 August 2021 (bulk drug and formulation).
- Bio-Medical Waste Management Rules, 2016 (G.S.R. 343(E), 28 March 2016), Schedule II.
- CPCB direction B-29016/04/06/PCI-I, 5 February 2014, under section 18(1)(b) of the Water and Air Acts (online monitoring for 17 categories of industries).
- Hazardous and Other Wastes (Management and Transboundary Movement) Rules, 2016 (G.S.R. 395(E), 4 April 2016), Schedule I and rules 4, 6, 8 and 20.
- MoEFCC, amendment to the Water Act consent guidelines, G.S.R. 63(E), 23 January 2026.
Related guides
- ZLD plants: how they work, cost and when they are mandatory
- STP vs ETP: what is the difference?
- Which STP outlet norms apply to my project?
- What does KLD mean?
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.