Skip to main content

Guide

RO plant price by capacity (LPH)

An industrial RO plant's price depends on its output in LPH, the feed water TDS, the pre-treatment it needs, the membrane make and the level of automation. Published market figures put a 1,000 LPH raw-water RO plant with pre-treatment at about ₹2.2 L – ₹4.9 L, excluding GST, building and storage tanks. RO for treated effluent costs considerably more.

Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·

Typical market price ranges by capacity

RO plants are sold by hourly output (LPH, litres of treated water per hour). The ranges below are converted to daily output on a 20-hour running day: KLD = LPH × 20 ÷ 1,000. A plant run for more or fewer hours delivers a different daily volume (see KLD meaning).

Typical market range (published figures, 2026) — not an NBW quotation. ±30%. Excludes GST, land, civil building and site work. Raw or process water RO, feed TDS below about 2,000 mg/l.
Plant size (permeate)KLD at 20 h/dayTurnkey price rangeRunning cost (O&M)
250 LPH5On requestOn request
500 LPH10₹1.5 L – ₹3.5 L₹25 – 45 per KL
1,000 LPH20₹2.2 L – ₹4.9 L₹23 – 41 per KL
2,000 LPH40₹3.4 L – ₹7.1 L₹21 – 37 per KL
3,000 LPH60₹4.5 L – ₹9.3 L₹19 – 34 per KL
5,000 LPH100₹6 L – ₹14 L₹15 – 30 per KL
10,000 LPH200₹10 L – ₹22 L₹13 – 27 per KL
20,000 LPH400₹18 L – ₹41 L₹11 – 25 per KL

Ranges are compiled from published Indian market figures and interpolated between capacities. They cover a turnkey raw-water RO plant: pre-treatment (multigrade and activated carbon filters, antiscalant dosing), the RO skid, a clean-in-place (CIP) system and the control panel. For 250 LPH and other small units, published figures vary too widely to give a fair range. For Navbharat Water's own estimate, request a quote.

What drives RO plant price

Cost driverHow it changes the price
Capacity (LPH)Bigger plants cost more in total but less per KLD, because the panel, CIP, engineering and commissioning do not grow in proportion.
Feed water TDS and qualityHigher TDS needs higher operating pressure and more membrane area for the same output. Hardness, iron, silica and organics decide how much pre-treatment is needed.
RecoveryRecovery (the share of feed water that becomes permeate) depends on the feed TDS and scaling tendency. Pushing recovery higher needs more stages, better antiscalant control and closer monitoring.
Pre-treatment trainMultigrade filter (MGF) for suspended solids, activated carbon filter (ACF) for chlorine and organics, a softener where hardness is high, and antiscalant dosing. Bore well, surface and municipal water each need a different train.
Membrane make and sizeBranded membranes cost more than generic ones. Small plants use 4-inch (4040) elements; larger plants use 8-inch (8040) elements in pressure vessels.
AutomationA basic panel with manual valves costs less than a PLC with auto-flushing, online TDS, pressure and flow instruments, and remote monitoring.
Skid material (MOC)Mild steel painted, stainless steel 304 or 316 frames and high-pressure piping change the price and the plant life, especially in corrosive or food and pharma settings.
CIP systemA dedicated clean-in-place tank, pump and cartridge filter add cost but protect the membranes and extend their life.

What an RO quotation should include

  • Design basis: feed water analysis (TDS, hardness, silica, iron), required permeate quality, LPH and running hours per day.
  • Membrane projection from the membrane maker's design software, showing recovery and expected permeate quality.
  • Equipment list with makes: feed and high-pressure pumps, filters, membranes, pressure vessels, dosing pumps, instruments, panel.
  • Pre-treatment, CIP system and skid material of construction.
  • Installation, commissioning, operator training, warranty and AMC terms.

What RO quotes often exclude

  • GST.
  • Plant-room building and foundations.
  • Raw water and treated water storage tanks.
  • Softener or DM (demineralisation) polishing, where boiler or process water needs it.
  • Reject (concentrate) disposal or treatment.
  • Power supply up to the plant panel, and piping beyond the skid.

Raw-water RO vs effluent-recycle RO

The prices above are for raw or process water: bore well, municipal or surface water with low TDS. RO that recycles treated sewage or industrial effluent costs considerably more. The feed carries organics, suspended solids and biological fouling, so it needs ultrafiltration or MBR ahead of the RO, more robust membranes, more frequent cleaning, and a plan for the reject. The upstream STP or ETP is a separate cost (see STP cost per KLD). For effluent and reuse systems, see membrane systems.

Drinking-water RO must meet IS 10500:2012 at the point of use. Very low TDS permeate may need remineralisation; state the required permeate quality when you ask for quotes.

Frequently asked questions

What is the price of a 1,000 LPH RO plant?

Published market figures put a 1,000 LPH raw-water RO plant with pre-treatment at about ₹2.2 L – ₹4.9 L, excluding GST, building and storage tanks. Feed TDS, membrane make and automation move the price within and beyond that range.

How many KLD is a 1,000 LPH RO plant?

At 20 hours running per day, 1,000 LPH gives 20 KLD of permeate (1,000 × 20 ÷ 1,000). At 24 hours it gives 24 KLD.

Why does effluent RO cost more than raw-water RO?

Treated effluent fouls membranes faster, so it needs ultrafiltration or MBR ahead of the RO, more robust membranes, more frequent cleaning and reject handling. Raw-water RO needs only filtration and antiscalant dosing ahead of the membranes.

Does an RO plant price include GST and storage tanks?

Usually not. Most quotes cover pre-treatment, the RO skid, CIP and panel, installed and commissioned. GST, the building, raw and treated water tanks, softener or DM polishing and reject disposal are often extra.

Which membrane size is used, 4040 or 8040?

Small plants generally use 4-inch (4040) elements and larger plants use 8-inch (8040) elements. The membrane maker's design software sets the number and arrangement for your feed water and output.

Sources

  1. DuPont Water Solutions, FilmTec Reverse Osmosis Membranes Technical Manual, form no. 45-D01504-en.
  2. Bureau of Indian Standards, IS 10500:2012, Drinking Water — Specification (Second Revision).

Related guides

Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.

How we calculate: our design method and sources. For a detailed quotation, request a quote.