A water softener removes hardness (calcium and magnesium) that causes scale, but leaves total dissolved solids (TDS) about the same. RO removes most dissolved salts, including hardness, but sends part of the water to drain as reject. If your borewell water is hard but TDS is acceptable, a softener is usually enough; if TDS is high, you need RO.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Hardness and TDS are not the same
- Hardness is the calcium and magnesium in the water, reported as mg/l of calcium carbonate (CaCO3). It causes white scale on taps, tiles and geysers, and soap does not lather well.
- TDS (total dissolved solids) is everything dissolved in the water: hardness salts plus sodium, chloride, sulphate and others. High TDS makes water taste salty or bitter.
- Water can be hard with moderate TDS, or have high TDS with little hardness. Test both before choosing a plant.
IS 10500:2012 limits for drinking water
| Parameter | Acceptable limit | Permissible limit (no alternative source) | IS 10500 table |
|---|---|---|---|
| Total hardness (as CaCO3) | 200 mg/l | 600 mg/l | Table 2 |
| Total dissolved solids | 500 mg/l | 2,000 mg/l | Table 1 |
What each one removes
| Factor | Water softener | RO plant |
|---|---|---|
| How it works | Ion exchange resin swaps calcium and magnesium for sodium | High-pressure pump pushes water through membranes that hold back dissolved salts |
| Removes hardness | Yes | Yes |
| Reduces TDS | No (TDS stays about the same) | Yes, most dissolved salts |
| Water to drain | Only during regeneration (brine and rinse water) | Continuous reject stream while running |
| Consumables | Salt for regeneration; resin over the years | Antiscalant, cartridge filters, membrane cleaning chemicals; membranes over the years |
| Power | Low (feed pump only) | Higher (high-pressure pump) |
| Pre-treatment | Filter for iron and turbidity if present | Sand and carbon filters, cartridge filter, antiscalant dosing |
When you need which
- Hardness high, TDS within the acceptable limit: a softener for the whole supply (bathing, washing, geysers) is usually enough.
- TDS above the acceptable limit, or the water tastes salty: RO, at least for drinking and cooking.
- Both high: many societies use a softener for the general supply and a smaller RO for drinking water, or RO for the full supply where TDS is very high.
- Iron, turbidity or bacteria in the borewell water need their own treatment (iron removal filter, sand filter, disinfection) whichever plant you choose.
Things to plan for
- Salt: a softener is regenerated with brine. Someone must keep the salt tank filled, and the salt used rises with the hardness and the volume treated.
- Brine and reject: softener regeneration water and RO reject are salty. Plan where they drain; reject can sometimes be used for floor washing or flushing.
- Sodium: softened water carries the sodium swapped for hardness. Where drinking water is a concern, give drinking points RO or a separate supply.
- Plant size: softeners and RO plants are sized in LPH, not KLD (see KLD meaning).
Navbharat Water designs softeners and RO plants for societies and buildings: see water treatment. Start with a lab test of hardness, TDS, iron and turbidity.
Limits are from IS 10500:2012 for drinking water. Water for boilers, cooling towers or process use has its own requirements.
Frequently asked questions
Does a water softener reduce TDS?
No. A softener swaps calcium and magnesium for sodium, so hardness falls but TDS stays about the same. To reduce TDS you need RO.
What is the acceptable hardness of drinking water in India?
IS 10500:2012 sets an acceptable limit of 200 mg/l total hardness as CaCO3, and a permissible limit of 600 mg/l where no alternative source is available.
Is RO water good for the whole society supply?
It can be, where TDS is high, but RO uses more power and rejects part of the water. Where only hardness is the problem, a softener for the general supply and RO for drinking water is often the better balance.
Sources
- Bureau of Indian Standards, IS 10500:2012, Drinking Water — Specification (Second Revision), Tables 1 and 2.
Related guides
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.