Guide
How a sewage treatment plant works, step by step
A sewage treatment plant cleans sewage in stages. Screens and a grease trap remove solids and oil. An equalisation tank stores the inflow. Bacteria in anoxic and aeration tanks break down the dissolved dirt. A settler separates the sludge, sand and carbon filters polish the water, and chlorine or UV disinfects it. The treated water can then be reused, and the sludge is thickened and dewatered.
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
The stages in order
- Screening: a bar screen at the inlet catches rags, plastic and other large solids that would block pumps and pipes.
- Oil and grease trap: oil and grease float to the top and are skimmed off. Essential where kitchens, canteens or hotels drain to the STP.
- Equalisation: a tank that stores the sewage as it arrives and feeds the plant at a steady rate, so the biology is not hit by morning and evening peaks.
- Anoxic tank: a mixed tank without air where bacteria convert nitrate back to nitrogen gas. Needed when the outlet norm limits total nitrogen.
- Aeration (biological treatment): air from blowers lets bacteria eat the dissolved organic matter (BOD) and convert ammonia. The technology is chosen here: MBBR, SBR, MBR or extended aeration.
- Settling: a tube settler or clarifier lets the bacteria (sludge) sink, and clear water flows out from the top. SBR settles in the same tank; MBR uses membranes instead.
- Filtration: a pressure sand filter (PSF) removes fine suspended solids, and an activated carbon filter (ACF) removes colour, odour and some remaining organics.
- Disinfection: chlorine (usually sodium hypochlorite) or UV kills the remaining bacteria so the water meets the faecal coliform limit.
- Treated-water reuse: the treated water goes to a storage tank for flushing, gardening or cooling-tower make-up, where the consent allows, or is discharged.
- Sludge handling: excess sludge goes to a sludge holding tank and is dewatered (filter press, bag filter or drying beds) before disposal.
What each stage does and what is sized
| Stage | What it does | What is sized |
|---|---|---|
| Screening | Removes large solids | Screen area and bar spacing, from peak flow and approach velocity |
| Oil & grease trap | Removes floating oil and grease | Tank volume and surface area, from peak flow |
| Equalisation | Stores inflow, evens out flow to the plant | Storage volume for the hours the plant is not running |
| Anoxic | Removes nitrogen (denitrification) | Tank volume, from the nitrate to be removed |
| Aeration (MBBR / SBR / MBR / extended aeration) | Removes BOD and ammonia | Tank or media volume from organic and ammonia load; air from oxygen demand |
| Settling | Separates sludge from treated water | Settler area from surface loading rate |
| Filtration (PSF / ACF) | Removes fine solids, colour and odour | Filter area from filtration rate; carbon volume from contact time |
| Disinfection | Kills pathogens | Chlorine dose and contact time, or UV dose |
| Treated-water storage | Holds water for reuse | Volume from the reuse demand |
| Sludge handling | Thickens and dewaters excess sludge | Sludge quantity, holding volume and dewatering capacity |
Where the technologies differ
- MBBR: plastic media in the aeration tank carry the bacteria; a separate settler follows.
- SBR: fill, aerate, settle and decant happen in one tank in timed cycles; no separate settler.
- MBR: membranes in the biological tank replace the settler and the sand filter.
- Extended aeration: a conventional activated sludge tank with a long aeration time and a clarifier.
For a side-by-side comparison see MBBR vs SBR vs MBR. How Navbharat Water sizes each stage is set out in our design method; the outlet the plant must reach is set by your consent (see STP norms).
Worked tank sizes for standard capacities (for example 50, 100 and 500 KLD) from our design engine will be added to this page.
Frequently asked questions
What are the main stages of an STP?
Preliminary treatment (screening, oil and grease removal, equalisation), biological treatment (anoxic and aeration), settling, tertiary treatment (sand and carbon filtration, disinfection), and sludge handling.
Why does an STP need an equalisation tank?
Sewage does not arrive evenly: there are morning and evening peaks, and little flow at night. The equalisation tank stores it and feeds the plant at a steady rate, and covers the hours when the plant is not running.
Is a sand and carbon filter always needed?
Most MBBR, SBR and extended aeration plants need them to meet strict outlet limits for suspended solids and to make the water fit for reuse. MBR plants usually do not, because the membranes already remove the fine solids.
What happens to the sludge?
Excess sludge is collected in a holding tank, dewatered in a filter press, bag filter or drying bed, and disposed of as the consent requires. Dried sludge from sewage is often used as manure where permitted.
Sources
- CPHEEO, Manual on Sewerage and Sewage Treatment Systems, Part A: Engineering, MoHUA, 2013.
- Metcalf & Eddy / AECOM, Wastewater Engineering: Treatment and Resource Recovery, 5th ed., McGraw-Hill, 2014.
Related guides
- MBBR vs SBR vs MBR compared
- How to calculate STP capacity in KLD
- Sewage BOD and COD, and how big the equalisation tank should be
Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.
How we calculate: our design method and sources. For a detailed quotation, request a quote.