Skip to main content

Guide

How a sewage treatment plant works, step by step

A sewage treatment plant cleans sewage in stages. Screens and a grease trap remove solids and oil. An equalisation tank stores the inflow. Bacteria in anoxic and aeration tanks break down the dissolved dirt. A settler separates the sludge, sand and carbon filters polish the water, and chlorine or UV disinfects it. The treated water can then be reused, and the sludge is thickened and dewatered.

Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·

The stages in order

  1. Screening: a bar screen at the inlet catches rags, plastic and other large solids that would block pumps and pipes.
  2. Oil and grease trap: oil and grease float to the top and are skimmed off. Essential where kitchens, canteens or hotels drain to the STP.
  3. Equalisation: a tank that stores the sewage as it arrives and feeds the plant at a steady rate, so the biology is not hit by morning and evening peaks.
  4. Anoxic tank: a mixed tank without air where bacteria convert nitrate back to nitrogen gas. Needed when the outlet norm limits total nitrogen.
  5. Aeration (biological treatment): air from blowers lets bacteria eat the dissolved organic matter (BOD) and convert ammonia. The technology is chosen here: MBBR, SBR, MBR or extended aeration.
  6. Settling: a tube settler or clarifier lets the bacteria (sludge) sink, and clear water flows out from the top. SBR settles in the same tank; MBR uses membranes instead.
  7. Filtration: a pressure sand filter (PSF) removes fine suspended solids, and an activated carbon filter (ACF) removes colour, odour and some remaining organics.
  8. Disinfection: chlorine (usually sodium hypochlorite) or UV kills the remaining bacteria so the water meets the faecal coliform limit.
  9. Treated-water reuse: the treated water goes to a storage tank for flushing, gardening or cooling-tower make-up, where the consent allows, or is discharged.
  10. Sludge handling: excess sludge goes to a sludge holding tank and is dewatered (filter press, bag filter or drying beds) before disposal.

What each stage does and what is sized

StageWhat it doesWhat is sized
ScreeningRemoves large solidsScreen area and bar spacing, from peak flow and approach velocity
Oil & grease trapRemoves floating oil and greaseTank volume and surface area, from peak flow
EqualisationStores inflow, evens out flow to the plantStorage volume for the hours the plant is not running
AnoxicRemoves nitrogen (denitrification)Tank volume, from the nitrate to be removed
Aeration (MBBR / SBR / MBR / extended aeration)Removes BOD and ammoniaTank or media volume from organic and ammonia load; air from oxygen demand
SettlingSeparates sludge from treated waterSettler area from surface loading rate
Filtration (PSF / ACF)Removes fine solids, colour and odourFilter area from filtration rate; carbon volume from contact time
DisinfectionKills pathogensChlorine dose and contact time, or UV dose
Treated-water storageHolds water for reuseVolume from the reuse demand
Sludge handlingThickens and dewaters excess sludgeSludge quantity, holding volume and dewatering capacity

Where the technologies differ

  • MBBR: plastic media in the aeration tank carry the bacteria; a separate settler follows.
  • SBR: fill, aerate, settle and decant happen in one tank in timed cycles; no separate settler.
  • MBR: membranes in the biological tank replace the settler and the sand filter.
  • Extended aeration: a conventional activated sludge tank with a long aeration time and a clarifier.

For a side-by-side comparison see MBBR vs SBR vs MBR. How Navbharat Water sizes each stage is set out in our design method; the outlet the plant must reach is set by your consent (see STP norms).

Worked tank sizes for standard capacities (for example 50, 100 and 500 KLD) from our design engine will be added to this page.

Frequently asked questions

What are the main stages of an STP?

Preliminary treatment (screening, oil and grease removal, equalisation), biological treatment (anoxic and aeration), settling, tertiary treatment (sand and carbon filtration, disinfection), and sludge handling.

Why does an STP need an equalisation tank?

Sewage does not arrive evenly: there are morning and evening peaks, and little flow at night. The equalisation tank stores it and feeds the plant at a steady rate, and covers the hours when the plant is not running.

Is a sand and carbon filter always needed?

Most MBBR, SBR and extended aeration plants need them to meet strict outlet limits for suspended solids and to make the water fit for reuse. MBR plants usually do not, because the membranes already remove the fine solids.

What happens to the sludge?

Excess sludge is collected in a holding tank, dewatered in a filter press, bag filter or drying bed, and disposed of as the consent requires. Dried sludge from sewage is often used as manure where permitted.

Sources

  1. CPHEEO, Manual on Sewerage and Sewage Treatment Systems, Part A: Engineering, MoHUA, 2013.
  2. Metcalf & Eddy / AECOM, Wastewater Engineering: Treatment and Resource Recovery, 5th ed., McGraw-Hill, 2014.

Related guides

Preliminary estimate, not for construction. Detailed design and quotation by NBW engineers.

How we calculate: our design method and sources. For a detailed quotation, request a quote.