Sewage treatment plants by capacity
100 KLD MBBR sewage treatment plant: sizes, footprint, power and budget
This 100 KLD MBBR sewage treatment plant is sized for 16 hours of running a day. Plot about 17.1 × 16.9 m (289 m²). Power: 17.2 kW connected, about 142 kWh a day. Computed outlet meets NGT 2019 (O.A. 1069/2018) for the parameters computed (BOD, COD, TSS, Total N). Budget: ₹28 L – ₹50 L (typical market range, not an NBW quotation).
Technically reviewed by Prashant Dwivedi, Co-Founder & Director ·
Design summary
| Item | Value |
|---|---|
| Design flow | 100 KLD |
| Flow over running hours | 6.25 m³/h (16 h/day) |
| Flow averaged over 24 h | 4.17 m³/h |
| Technology | MBBR |
| Plot (footprint) | 17.1 × 16.9 m (289 m²) |
| Connected load | 17.2 kW |
| Operating load | 9.3 kW |
| Energy per day | 142 kWh |
| Energy per m³ | 1.42 kWh/m³ |
| Blower air (all duty blowers) | 183 Nm³/h |
| Design method | NBW practice |
Treatment units and sizes
| Unit | Purpose | Volume | Size | Sizing basis |
|---|---|---|---|---|
| Equalisation tank | stores and evens out the inflow | 50.5 m³ | 3.8 × 3.8 × 3.5 m | stores the inflow of the 8 h a day the plant does not run, x 1.5 for peaks; air for mixing only, no treatment credit |
| MBBR anoxic tank | removes nitrate (denitrification) | 6.4 m³ | 1.35 × 1.35 × 3.5 m | anoxic (denitrification), 1 h on the running flow; nitrate recycle 3 x |
| MBBR tank, 2 stages (sieve baffle) | biological treatment: BOD and ammonia removal | 42.3 m³ | 3.45 × 3.5 × 3.5 m | larger of 6 h on the running flow and the tank for the media needed for BOD + ammonia removal; media 16.9 m3 (40 % fill), 2 stages, fine-bubble air |
| Secondary clarifier (hopper bottom) | settles the biological sludge | 37.8 m³ | 3.55 × 3.55 × 3 m | clarifier by surface loading, 6.0 h |
| Chlorine contact tank | disinfection (chlorine contact) | 3.2 m³ | 1.65 × 0.55 × 3.5 m | chlorine contact on the running flow |
| Pressure sand filter, FRP 36x72 inch | removes suspended solids | Ø 0.91 m × 1.83 m high | 6.2 m3/h at 9.5 m/h filtration velocity | |
| Activated carbon filter, MS 1200 mm, 4 mm FRP lined | removes colour, odour and chlorine | Ø 1.2 m × 1.8 m high | 6.2 m3/h at 5.5 m/h filtration velocity | |
| Treated water tank | stores the treated water | 33.6 m³ | 3.1 × 3.1 × 3.5 m | treated water storage, about 8 h of average flow |
| Sludge holding tank | holds the excess sludge | 9 m³ | 1.6 × 1.6 × 3.5 m | about 7 days of sludge, air mixed |
| Twin lobe air blower | air for aeration and mixing | 183 Nm3/h at 4.5 m water column, 1 working + 1 standby (serves eq, mbbr, sludge) |
Tank sizes are length × width × depth; vessel sizes are diameter × height.
Water quality, stage by stage
| Stage | BOD | COD | TSS | NH₃-N | Total N | Oil & grease |
|---|---|---|---|---|---|---|
| Inlet | 250 | 500 | 250 | 40 | 40 | 30 |
| Basket screen (inlet chamber) | 250 | 500 | 250 | 40 | 40 | 30 |
| Grit chamber | 250 | 500 | 250 | 40 | 40 | 30 |
| Equalisation tank | 250 | 500 | 250 | 40 | 40 | 30 |
| MBBR anoxic tank | 159.7 | 330.3 | 250 | 40 | 17.4 | 30 |
| MBBR bioreactor | 8 | 45 | 250 | 1 | 8.5 | 6 |
| Secondary clarifier | 6.8 | 42.8 | 30 | 1 | 8.5 | 6 |
| Disinfection | 6.8 | 42.8 | 30 | 1 | 8.5 | 6 |
| Pressure sand filter | 5.1 | 39.6 | 15 | 1 | 8.5 | 6 |
| Activated carbon filter | 3.3 | 25.7 | 15 | 1 | 8.5 | 6 |
| Outlet | 3.3 | 25.7 | 15 | 1 | 8.5 | 6 |
Outlet vs NGT 2019 (O.A. 1069/2018)
| Parameter | Limit | Computed outlet | Result |
|---|---|---|---|
| BOD | ≤ 10 | 3.3 | Within limit |
| COD | ≤ 50 | 25.7 | Within limit |
| TSS | ≤ 20 | 15 | Within limit |
| Total N | ≤ 10 | 8.5 | Within limit |
Design assumptions
- Raw inlet BOD 250 mg/L
- Raw inlet COD 500 mg/L
- Raw inlet TSS 250 mg/L
- Raw inlet TKN 40 mg/L
- Raw inlet oil and grease 30 mg/L
- Design temperature 15–32 °C
- Checked against: NGT 2019 (O.A. 1069/2018)
- Plant running 16 hours a day
- Inlet quality: typical domestic sewage (CPHEEO 2013), no lab report; COD = 2 x BOD
Design checks
- screen type: a channel bar screen reaches only 0.41 m/s at a buildable width: basket screen (10 mm) in a 1 x 1 m inlet chamber instead
- alkalinity after nitrification (before dosing): short of alkalinity: NaHCO3 dosed to keep pH >= 6.8
Budget
Typical market range (published figures, 2026) — not an NBW quotation
| Capacity | STP — MBBR |
|---|---|
| 100 KLD | ₹28 L – ₹50 L |
| Capacity | STP — MBBR |
|---|---|
| 100 KLD | ₹10 – 22 per KL |
These are published market figures, not Navbharat Water's prices. For our own estimate for your project, request a quote.
What quotes often exclude
- GST
- Land and civil building / shed
- Site work: excavation, piling, dewatering
- Power connection up to the plant panel
- Consent (CTE / CTO) fees and liaison
- Operation and maintenance after commissioning
Check your SPCB consent
The State Pollution Control Board consent (CTE / CTO) for your project sets the outlet limits the plant must meet, which can be stricter than the national norm. Check it before you finalise the design: STP discharge norms explained.
Frequently asked questions
What size of tanks does a 100 KLD MBBR STP need?
About 183 m3 of tanks in all: equalisation tank 50.5 m3; mbbr anoxic tank 6.4 m3; mbbr tank 42.3 m3; secondary clarifier (hopper bottom) 37.8 m3; chlorine contact tank 3.2 m3; treated water tank 33.6 m3; sludge holding tank 9 m3.
How much space and power does a 100 KLD MBBR STP need?
A plot about 17.1 x 16.9 m including the equipment room; 17.2 kW connected, 9.3 kW running, about 142 kWh a day (1.42 kWh per m3) at 16 h a day.
Does a 100 KLD MBBR STP meet NGT 2019?
Computed outlet BOD 3.3, TSS 15 mg/L against NGT 2019 BOD 10, COD 50, TSS 20 mg/L: within the limits.
Related
- What size STP does a 150-flat society need?
- STP cost per KLD in India
- STP capacity calculator
- How to calculate STP capacity
- MBBR vs SBR vs MBR
- What KLD means (KLD to LPH)