EuroTec ETUF-9040R UF Membrane Module
UF Membranes · UF Module — 40 m²

EuroTec ETUF-9040R UF Membrane Module

40 m² · PVDF · 0.025 µm · Ø344×1600mm · 2.5 bar · pH 1–12 · 6-log bacteria

Compact 40 m² PVDF hollow-fibre UF module for smaller-footprint installations. Same certified membrane technology as the 9060R in a shorter 1600mm housing. Suited for decentralised water treatment, hotel water polishing, and RO pre-treatment on mid-size systems.

Specifications

  • 40 m²
  • PVDF
  • 0.025 µm
  • Ø344×1600mm
  • 2.5 bar
  • pH 1–12
  • 6-log bacteria

Where it's used

Related solutions

What it is and when to use it

The EuroTec ETUF-9040R is a 40 m² outside-in PVDF hollow-fibre UF module, 1,600 mm long and Ø344 mm, with 0.025 µm pores and 6-log bacteria removal. Choose it for smaller plants or where headroom is limited, since it uses the same membrane as the 9060R in a shorter module.

According to the EuroTec brochure, the 9040R shares its 344 mm diameter, 1.5″ FNPT feed, concentrate and filtrate connections and 2.5 bar maximum feed pressure with the 9060R, but is 740 mm shorter (1,600 mm vs 2,340 mm) and carries 40 m² instead of 60 m² of membrane.

That makes it a good fit for low-flow skids, containerised units and plant rooms with restricted height. It can also be used where a plant needs finer capacity steps than 60 m² modules allow. The membrane is EuroTec's NSF-certified high anti-fouling PVDF with a narrow pore-size distribution, operated outside-in so it can be cleaned by backwash and air scouring.

Use it for

  • Small and mid-size UF plants and packaged skids
  • Installations with limited headroom
  • RO pre-treatment on smaller RO trains
  • Decentralised water treatment and water polishing

How to choose

  1. Size module count from net flow, design flux and 40 m² per module
  2. Check the available height for the 1,600 mm module plus piping and service clearance
  3. Confirm feed pressure is within the 2.5 bar maximum
  4. Plan backwash, air scour and chemical cleaning based on feed quality
  5. Compare with the 9060R if height allows; fewer, larger modules can simplify larger plants

Frequently asked questions

How does the ETUF-9040R differ from the ETUF-9060R?

Both use the same PVDF outside-in membrane, with a 344 mm diameter, 1.5″ FNPT connections and 2.5 bar maximum feed pressure. The 9040R is 1,600 mm long with 40 m² of membrane, while the 9060R is 2,340 mm long with 60 m². The 9040R suits smaller plants and spaces with limited height.

What size of plant suits the ETUF-9040R?

The 9040R suits small and mid-size systems where 60 m² modules would provide more capacity than needed or where height is restricted. Module count depends on your net flow and design flux, which depends on feed water quality. Share your flow and water analysis and our engineers will size the system.

What does 6-log bacteria removal mean?

A 6-log reduction means the membrane removes 99.9999% of bacteria, as stated in EuroTec's specifications. With a 0.025 µm pore size, the UF membrane acts as a physical barrier to bacteria and suspended solids, which is why UF is widely used for drinking water, reuse and RO pre-treatment.